Data Transformation
  • 02 May 2024
  • 1 Minute to read
  • Dark
    Light
  • PDF

Data Transformation

  • Dark
    Light
  • PDF

Article summary

This step allows users to adjust the size of the milled crown data by scaling it along the X, Y, and Z axes.
data_transformation_1

  • Upon entering, you are prompted to select data for transformation. Choose your milled crown data and click "Confirm."
    data_transformation_2
  • By default, scaling is set to apply uniformly across all axes with a single value. To set different values for each axis, uncheck the "Uniform" box.
    Try different values to see how the data size changes accordingly.
    🔎Note
    As the milled zirconia crown's scale is enlarged before sintering, the crown's scale must be reduced before the fitting test. To determine the appropriate scaling value, refer to the contraction rate written on the zirconia block.
    data_transformation_5
  • You can revert to the default values by clicking "Reset."
    data_transformation_4
  • When you have decided on the required scaling value, click the "Apply" icon to permanently apply changes to the data across all steps.
    ⚠️Caution
    After applying changes, the "Reset" feature will not revert to the initial data scale.

    data_transformation_5


Was this article helpful?

What's Next